As peritoneal dialysis (PD)-related fungal infection is associated with a high mortality rate, the international guidelines recommend immediate removal of the PD catheter in conjunction with at least 2-weeks of antifungal treatment.Some authors have reported successful management of such cases without removing the PD catheter - b-0665-cr-bstr by instilling an antifungal lock into the retained PD catheter.However, the use of antifungal locks has generally not been well accepted as the standard emma shipley fabric sale treatment for fungal peritonitis in PD patients.We report two cases where antifungal lock were performed in PD patients presented with PD-related fungal infection that not only had no effect on abating the infection but also causing paradoxical outcomes.Keywords: Peritoneal dialysis (PD), Paradoxical, Fungal peritonitis, Intracatheter.